The CD22 Series delivers high-end accuracy in the smallest form factor of its class, combining a hybrid optical lens with advanced feedback circuitry for 1 μm repeatability. Designed for space-constrained environments, it offers robust performance, intuitive operation, and flexible connectivity, making it the ideal solution for precise measurements in compact setups.
Features & Benefits
- Ultra-compact design with built-in amplifier and display saves space and simplifies installation.
- Tri_CORE technology delivers ±0.1% F.S. linearity and up to 1 μm repeat accuracy for precise measurements.
- Easy-to-read 4-digit display enables quick on-site verification and simple setup.
- Supports analog outputs and RS-485 communication for seamless integration with automation systems.
- Automatic sampling mode ensures stable, high-speed measurements even on low-reflective surfaces.
Function
| Specification Order # |
CD22-15A / CD22-15V (64PMI311 / 64PMI313) |
CD22-35A / CD22-35V (64PMI316 / 64PMI318) |
CD22-100A2 / CD22-100V2 (64PMI321 / 64PMI323) |
|---|---|---|---|
| Analog Current type | CD22-15AM12 | CD22-35AM12 | CD22-100AM122 |
| Analog Voltage type | CD22-15VM12 | CD22-35VM12 | CD22-100VM122 |
| Center of measurement range | 15 mm | 35 mm | 100 mm |
| Measurement range | ±5 mm (10 mm F.S.) | ±15 mm (30 mm F.S.) | ±50 mm (100 mm F.S.) |
| Medium/Light source Wavelength | Red semiconductor laser, wavelength: 655 nm | ||
| Light source Max. output | 390 μW | 1 mW | 1 mW |
| Laser class IEC/JIS | Class 1 | Class 1 | Class 2 *¹ |
| Laser class FDA *² | Class 1 *² | Class 1 *² | Class 2 *¹ |
| Spot size *³ | Approx. 0.5 x 0.7 mm | Approx. 0.45 x 0.8 mm | Approx. 0.6 x 0.7 mm |
| Linearity | ±0.1% F.S. | ||
| Repeat accuracy *⁴ | 1 μm | 6 μm | 20 μm |
| Sampling period | 500 μs / 1000 μs / 2000 μs / 4000 μs / AUTO | ||
| Temperature drift | ±0.02% / °C F.S. | ±0.05% / °C F.S. | |
| Indicators | Laser emission indicator (green) / zero reset indicator (red) / output indicator (orange) / mode indicator (red) | ||
| External input | Laser OFF, teaching, sample & hold, one-shot, zero reset (selectable) | ||
| Analog output Current type | 4 to 20 mA, Load impedance: 300 Ω or less | ||
| Analog output Voltage type | 0 to 10 V, output impedance: 100 Ω | ||
| Control output | NPN/PNP open collector (selectable by setting), Max. 100 mA / 30 VDC, residual voltage 1.8 V | ||
| Supply voltage | 12 to 24 VDC ±10% *⁵ | ||
| Supply Current consumption | 70 mA or less (at 24 VDC) | ||
| Connection type | Cable type: Cable length: 2 m, Ø4.5 Pigtail type: Cable with M12, 5-pin connector, 300 mm length |
||
| Protection circuit | Reverse connection protection, overcurrent protection | ||
| Environmental resistance Degree of protection | IP67 (including joint of pig tail type) | ||
| Environmental resistance Ambient temp/humidity | -10 to +50°C / 35 to 85% RH (no freezing or condensation) | ||
| Environmental resistance Ambient illuminance | Incandescent lamp 3,000 lx or less | ||
| Vibration resistance | 10 to 55 Hz, double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | ||
| Shock resistance | Approx. 50 G (500 m/s²), 3 times in each of the X, Y, and Z directions | ||
| Applicable regulations | EMC directive (2004/108/EC) / FDA regulations (21 CFR 1040.10) | ||
| Applicable standards | EN 60947-5-7 | ||
| Warm-up time | Approx. 5 minutes | ||
| Material Housing | Aluminum die-cast front cover: PPSU Display: PET Cable: PVC | ||
| Material Weight | Cable type: Approx. 90 g Pig tail type: Approx. 60 g | ||
| Specification Order # |
CD22-15-485M12 (64PMI315) |
CD22-35-485M12 (64PMI320) |
CD22-100-485M122 (64PMI325) |
|---|---|---|---|
| Center of measurement range | 15 mm | 35 mm | 100 mm |
| Measurement range | ±5 mm | ±15 mm | ±50 mm |
| F.S. (full scale) | 10 mm | 30 mm | 100 mm |
| Medium/Wavelength | Red semiconductor laser, wavelength: 655 nm | ||
| Light source Max. output | 390 μW | 1 mW | 1 mW |
| Laser class IEC/JIS | Class 1 | Class 1 | Class 2 *¹ |
| Laser class FDA | Class 1 *² | Class 1 *² | Class 2 *² |
| Spot size *³ | Approx. 0.5 x 0.7 mm | Approx. 0.45 x 0.8 mm | Approx. 0.6 x 0.7 mm |
| Linearity | ±0.1% F.S. | ||
| Repeat accuracy *⁴ | 1 μm | 6 μm | 20 μm |
| Sampling period | 500 μs / 1000 μs / 2000 μs / 4000 μs / AUTO | ||
| Temperature drift | ±0.02% / °C F.S. | ±0.05% / °C F.S. | |
| Indicators | Laser emission indicator (green) / zero reset indicator (red) / output indicator (orange) / mode indicator (red) | ||
| Serial interface *⁵ | RS-485 half duplex communication (9.6 k to 1,250 kbps) | ||
| Supply voltage | 12 to 24 VDC ±10% | ||
| Current consumption | 70 mA or less (at 24 VDC) | ||
| Control output | NPN/PNP open collector (selectable by setting), Max. 100 mA / 30 VDC, residual voltage 1.8 V | ||
| Connection type | Pig tail type: Cable with M12, 5-pin connector, 300 mm length | ||
| Protection circuit | Reverse connection protection, overcurrent protection | ||
| Environmental resistance Degree of protection | IP67 (including joint of pig tail type) | ||
| Environmental resistance Ambient temp/humidity | -10 to +50°C / 35 to 85% RH (no freezing or condensation) | ||
| Environmental resistance Ambient illuminance | Incandescent lamp 3,000 lx or less | ||
| Vibration resistance | 10 to 55 Hz, double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | ||
| Shock resistance | Approx. 50 G (500 m/s²), 3 times in each of the X, Y, and Z directions | ||
| Applicable regulations | EMC directive (2004/108/EC) / FDA regulations (21 CFR 1040.10) | ||
| Applicable standards | EN 60947-5-2 | ||
| Warm-up time | Approx. 5 minutes | ||
| Material Housing | Aluminum die-cast Front cover: PPSU Display: PET Cable: PVC | ||
| Material Weight | Approx. 60 g | ||