Close

CD22 Series

The CD22 Series delivers high-end accuracy in the smallest form factor of its class, combining a hybrid optical lens with advanced feedback circuitry for 1 μm repeatability. Designed for space-constrained environments, it offers robust performance, intuitive operation, and flexible connectivity, making it the ideal solution for precise measurements in compact setups. 

Download Brochure
Features & Benefits
  • Ultra-compact design with built-in amplifier and display saves space and simplifies installation. 
  • Tri_CORE technology delivers ±0.1% F.S. linearity and up to 1 μm repeat accuracy for precise measurements. 
  • Easy-to-read 4-digit display enables quick on-site verification and simple setup. 
  • Supports analog outputs and RS-485 communication for seamless integration with automation systems. 
  • Automatic sampling mode ensures stable, high-speed measurements even on low-reflective surfaces. 
Function
Specification
Order #
CD22-15A / CD22-15V
(64PMI311 / 64PMI313)
CD22-35A / CD22-35V
(64PMI316 / 64PMI318)
CD22-100A2 / CD22-100V2
(64PMI321 / 64PMI323)
Analog Current type CD22-15AM12 CD22-35AM12 CD22-100AM122
Analog Voltage type CD22-15VM12 CD22-35VM12 CD22-100VM122
Center of measurement range 15 mm 35 mm 100 mm
Measurement range ±5 mm (10 mm F.S.) ±15 mm (30 mm F.S.) ±50 mm (100 mm F.S.)
Medium/Light source Wavelength Red semiconductor laser, wavelength: 655 nm
Light source Max. output 390 μW 1 mW 1 mW
Laser class IEC/JIS Class 1 Class 1 Class 2 *¹
Laser class FDA *² Class 1 *² Class 1 *² Class 2 *¹
Spot size *³ Approx. 0.5 x 0.7 mm Approx. 0.45 x 0.8 mm Approx. 0.6 x 0.7 mm
Linearity ±0.1% F.S.
Repeat accuracy *⁴ 1 μm 6 μm 20 μm
Sampling period 500 μs / 1000 μs / 2000 μs / 4000 μs / AUTO
Temperature drift ±0.02% / °C F.S. ±0.05% / °C F.S.
Indicators Laser emission indicator (green) / zero reset indicator (red) / output indicator (orange) / mode indicator (red)
External input Laser OFF, teaching, sample & hold, one-shot, zero reset (selectable)
Analog output Current type 4 to 20 mA, Load impedance: 300 Ω or less
Analog output Voltage type 0 to 10 V, output impedance: 100 Ω
Control output NPN/PNP open collector (selectable by setting), Max. 100 mA / 30 VDC, residual voltage 1.8 V
Supply voltage 12 to 24 VDC ±10% *⁵
Supply Current consumption 70 mA or less (at 24 VDC)
Connection type Cable type: Cable length: 2 m, Ø4.5
Pigtail type: Cable with M12, 5-pin connector, 300 mm length
Protection circuit Reverse connection protection, overcurrent protection
Environmental resistance Degree of protection IP67 (including joint of pig tail type)
Environmental resistance Ambient temp/humidity -10 to +50°C / 35 to 85% RH (no freezing or condensation)
Environmental resistance Ambient illuminance Incandescent lamp 3,000 lx or less
Vibration resistance 10 to 55 Hz, double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
Shock resistance Approx. 50 G (500 m/s²), 3 times in each of the X, Y, and Z directions
Applicable regulations EMC directive (2004/108/EC) / FDA regulations (21 CFR 1040.10)
Applicable standards EN 60947-5-7
Warm-up time Approx. 5 minutes
Material Housing Aluminum die-cast front cover: PPSU Display: PET Cable: PVC
Material Weight Cable type: Approx. 90 g Pig tail type: Approx. 60 g

 

Specification
Order #
CD22-15-485M12
(64PMI315)
CD22-35-485M12
(64PMI320)
CD22-100-485M122
(64PMI325)
Center of measurement range 15 mm 35 mm 100 mm
Measurement range ±5 mm ±15 mm ±50 mm
F.S. (full scale) 10 mm 30 mm 100 mm
Medium/Wavelength Red semiconductor laser, wavelength: 655 nm
Light source Max. output 390 μW 1 mW 1 mW
Laser class IEC/JIS Class 1 Class 1 Class 2 *¹
Laser class FDA Class 1 *² Class 1 *² Class 2 *²
Spot size *³ Approx. 0.5 x 0.7 mm Approx. 0.45 x 0.8 mm Approx. 0.6 x 0.7 mm
Linearity ±0.1% F.S.
Repeat accuracy *⁴ 1 μm 6 μm 20 μm
Sampling period 500 μs / 1000 μs / 2000 μs / 4000 μs / AUTO
Temperature drift ±0.02% / °C F.S. ±0.05% / °C F.S.
Indicators Laser emission indicator (green) / zero reset indicator (red) / output indicator (orange) / mode indicator (red)
Serial interface *⁵ RS-485 half duplex communication (9.6 k to 1,250 kbps)
Supply voltage 12 to 24 VDC ±10%
Current consumption 70 mA or less (at 24 VDC)
Control output NPN/PNP open collector (selectable by setting), Max. 100 mA / 30 VDC, residual voltage 1.8 V
Connection type Pig tail type: Cable with M12, 5-pin connector, 300 mm length
Protection circuit Reverse connection protection, overcurrent protection
Environmental resistance Degree of protection IP67 (including joint of pig tail type)
Environmental resistance Ambient temp/humidity -10 to +50°C / 35 to 85% RH (no freezing or condensation)
Environmental resistance Ambient illuminance Incandescent lamp 3,000 lx or less
Vibration resistance 10 to 55 Hz, double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
Shock resistance Approx. 50 G (500 m/s²), 3 times in each of the X, Y, and Z directions
Applicable regulations EMC directive (2004/108/EC) / FDA regulations (21 CFR 1040.10)
Applicable standards EN 60947-5-2
Warm-up time Approx. 5 minutes
Material Housing Aluminum die-cast Front cover: PPSU Display: PET Cable: PVC
Material Weight Approx. 60 g