The CD2H Series combines fastest-in-class repeat accuracy of 0.25 μm with an ultra-sensitive ATMOS C-MOS image sensor for real-time, feedback-free measurement. Designed for versatility, it supports extended ranges up to 1,200 mm, features an easy-to-read OLED display, and offers IO-Link connectivity for seamless integration and smart factory readiness.
Features & Benefits
- Delivers fastest-in-class 0.25 μm repeat accuracy for ultra-precise measurements.
- Achieves high-speed performance with a 133.3 μs sampling period for rapid data acquisition.
- Equipped with ATMOS image sensor and feedback-free shutter for real-time measurement without delays.
- Features an easy-to-read OLED display with multilingual menus and waveform visualization for simplified setup.
- Includes buffering capability for up to 16,000 measurements to enhance traceability and process control.
Function
| Specification | CD2H-30A (64PMI332) |
CD2H-50A (64PMI334) |
CD2H-130 (64PMI336) |
CD2H-245Z (64PMI338) |
CD2H-350Z (64PMI340) |
CD2H-700Z (64PMI342) |
|---|---|---|---|---|---|---|
| Order No. Pigtail Cable | CD2H-30M12A (64PMI333) |
CD2H-50M12A (64PMI335) |
CD2H-130M12 (64PMI337) |
CD2H-245M12Z (64PMI339) |
CD2H-350M12Z (64PMI341) |
CD2H-700M12Z (64PMI343) |
| Center of Measurement range | 30 mm | 50 mm | 130 mm | 245 mm | 350 mm | 700 mm |
| Measurement range | ±5 mm | ±10 mm | ±70 mm | ±175 mm | ±250 mm | ±500 mm |
| Medium/Wavelength | Red semiconductor laser, wavelength: 655 nm | |||||
| Light source Max. output | 0.39 mW | 1 mW | ||||
| Laser class IEC/JIS / FDA *¹ | CLASS 1 / CLASS 1 | CLASS 2 / CLASS II | ||||
| Spot size *² | ø50 μm | ø70 μm | ø0.3 μm | ø0.5 μm | ø0.6 μm | ø1.0 μm |
| Linearity | ±0.1% of F.S. | ±0.1% of F.S. (200 to 700 mm) ±0.3% of F.S. (700 to 1200 mm) |
||||
| Resolution *³ | 0.25 μm | 0.25 μm | 4 μm | 10 μm | 20 μm | 100 μm |
| Repeat accuracy *⁴ | 0.25 μm | 0.25 μm | 4 μm | 10 μm | 20 μm | 100 μm |
| Sampling period *⁵ | 133.3 μs / 150 μs / 200 μs / 300 μs / 500 μs / 1 ms / 2 ms / 5 ms / Auto | |||||
| Temperature characteristics *⁶ | ±0.06% of F.S./°C | |||||
| Weight | Cable models: Approx. 140 g Connector models: Approx. 90 g | |||||
| Specifications | Rev. 1.1 | |||||
| IO-Link Baud rate | COM3 (230.4 kbps) | |||||
| IO-Link Number of process input data bytes | 6 bytes | |||||
| IO-Link Minimum cycle time | 0.7 ms | |||||
| Control output (DO1/DO2)*⁷ No. of outputs | 2 (DO1 can be switched to IO-Link.) | |||||
| Control output (DO1/DO2)*⁷ Polarity | NPN/PNP, open collector or Push-Pull (selectable by setting) | |||||
| Control output (DO1/DO2)*⁷ Current | Max. 100 mA / 24 VDC, residual voltage 1.8 V or less | |||||
| Analog output QA*⁸ Current | 4 to 20 mA, load impedance: 300 Ω or less | |||||
| Analog output QA*⁸ Voltage | 0 to 10 V, output impedance: 100 Ω or less | |||||
| Analog output QA*⁸ Switchable | Switchable between Off, Multi operations, Hold, Zero point teach, and Laser off | |||||
| Connection Cable | Cable: Ø4.5 mm, 2 m cable | |||||
| Connection Pigtail cable | Pigtail cable: Ø4.5 mm, 300 mm cable with M12 5-pin connector | |||||
| Connection Minimum bending radius | Cable diameter x 2 (when fixed in place), cable diameter x 6 (when movable) | |||||
| Specification | CD2H-30-485M12A (Contact Sales) |
CD2H-50-485M12A (Contact Sales) |
CD2H-130-485M12 (Contact Sales) |
CD2H-245-485M12Z (Contact Sales) |
CD2H-350-485M12Z (Contact Sales) |
CD2H-700-485M12Z (Contact Sales) |
|---|---|---|---|---|---|---|
| Center of Measurement range | 30 mm | 50 mm | 130 mm | 245 mm | 350 mm | 700 mm |
| Measurement range | ±5 mm | ±10 mm | ±70 mm | ±175 mm | ±250 mm | ±500 mm |
| Medium/Wavelength | Red semiconductor laser, wavelength: 655 nm | |||||
| Light source Max. output | 0.39 mW | 1 mW | ||||
| Laser class IEC/JIS / FDA *¹ | CLASS 1 / CLASS 1 | CLASS 2 / CLASS II | ||||
| Spot size *² | ø50 μm | ø70 μm | ø0.3 μm | ø0.5 μm | ø0.6 μm | ø1.0 μm |
| Linearity | ±0.1% of F.S. | ±0.1% of F.S. (200 to 700 mm) ±0.3% of F.S. (700 to 1200 mm) |
||||
| Resolution *³ | 0.25 μm | 0.25 μm | 4 μm | 10 μm | 20 μm | 100 μm |
| Repeat accuracy *⁴ | 0.25 μm | 0.25 μm | 4 μm | 10 μm | 20 μm | 100 μm |
| Sampling period *⁵ | 133.3 μs / 150 μs / 200 μs / 300 μs / 500 μs / 1 ms / 2 ms / 5 ms / Auto | |||||
| Temperature characteristics *⁶ | ±0.06% of F.S./°C | |||||
| Communication specifications | ||||||
| Data transmission | RS-485 half-duplex communication, start-stop synchronization | |||||
| Protocol | Modbus RTU | |||||
| Baud rate | 9600 bps / 19200 bps / 38400 bps / 57600 bps / 115.2 Kbps / 230.4 Kbps / 1 Mbps / 2 Mbps / 4 Mbps | |||||
| Data length | 8 bit | |||||
| Parity | Even / Odd / None | |||||
| Stop bit | 1 bit, 2 bit | |||||
| Control Output (DO1) / External Input *⁷ | ||||||
| No. of outputs | 1 (switchable to external input) | |||||
| Polarity | NPN/PNP, open collector or Push-Pull (selectable by setting) | |||||
| Current | Max. 100 mA / 24 VDC, residual voltage 1.8 V or less | |||||
| External input *⁷ | Teach 1 / Teach 2 / Offset clear / Laser off / Input hold / Buffering / Buffer clear / Rise: Teach 1, Fall: Teach 2 / Rise: Teach 2, Fall: Teach 1 | |||||
| Connection | Pigtail cable: Ø4.5 mm, 300 mm cable with M12 5-pin connector | |||||
| Connection Minimum bending radius | Cable diameter × 2 (when fixed in place), cable diameter × 6 (when movable) | |||||